Abstract The mechanical structure and circuits of a new type of automatic zeroing device are designed, which can make the precision of DZW-type gravimeters’ zero conrol reach to 40×10 -8 ms-2 .The design not only accelerates the zeroing operation but also avoids excess and lack of adjustment as well. Moreover, the device can fulfill automatic zero by distant control.
Key words :
gravimeter
automatic zero
machine configuration
circuits
distant control
Received: 01 January 1900
Corresponding Authors:
Wu Pengfei
Cite this article:
Wu Pengfei,Hu Guoqing,and Du Ruilin. DESIGN OF AUTOMATICALLY ZEROING DEVICE OF DZW-TYPE GRAVIMETER[J]. , 2009, 29(2): 146-148.
Wu Pengfei,Hu Guoqing,and Du Ruilin. DESIGN OF AUTOMATICALLY ZEROING DEVICE OF DZW-TYPE GRAVIMETER[J]. jgg, 2009, 29(2): 146-148.
URL:
http://www.jgg09.com/EN/ OR http://www.jgg09.com/EN/Y2009/V29/I2/146
[1]
WEI Jin,Lü Pinji,HAO Hongtao,WANG Jianwei,LI Ning,HU Minzhang. Study on the Anomalies of the Double Frequency Microseisms before Yingcheng MS 4.9 Earthquake [J]. jgg, 2022, 42(1): 88-95.
[2]
DENG Youmao,WANG Zhenliang,SUN Chengye. Comparative Analysis of the CG Gravimeters Performance [J]. jgg, 2021, 41(4): 432-435.
[3]
HONG Xuyu, QIN Shuanglong. Analysis of Seismic Response Capability of Fujian Gravity Network [J]. jgg, 2021, 41(3): 238-242.
[4]
. [J]. jgg, 2020, 40(S2): 1-4.
[5]
. [J]. jgg, 2020, 40(S2): 5-8.
[6]
. [J]. jgg, 2020, 40(S2): 9-12.
[7]
. [J]. jgg, 2020, 40(S1): 5-9.
[8]
. [J]. jgg, 2020, 40(S1): 1-4.
[9]
. [J]. jgg, 2020, 40(S1): 141-143.
[10]
. [J]. jgg, 2020, 40(S1): 14-18.
[11]
REN MinshuanSHANG Yongjie, ZHENG Wenke, KANG Shengjun,ZHAO Pi. Overview of the Adjustment Method of Laser FiberAlignment for Absolute Gravimeter [J]. jgg, 2020, 40(9): 981-984.
[12]
HU Yuanwang,ZOU Tong,ZHANG Li,MA Wugang. Analysis and Simulation of Two-Stage Ultra-Low Frequency VibrationIsolation System Based on PID Feedback [J]. jgg, 2020, 40(9): 976-980.
[13]
LI Hang,CHEN Xiaodong,XU Jianqiao,SUN Heping,ZHANG Miaomiao,HAN Yufei. Comparison of Noise Levels between Gravimeters and Co-Located Seismometers at the Seismic Frequency Band [J]. jgg, 2020, 40(8): 843-848.
[14]
LIANG Xiao, XU Rugang, LIN Chenghao, CHU Fei, XIAO Weipeng, WANG Fei. Drift Characteristics of CG-5 Gravimeter and the Method of Time-Division Adjustment [J]. jgg, 2020, 40(6): 655-660.
[15]
LANG Junjian, LIANG Xinghui, TU Haibo, LIU Leijun, HU Ming, HE Jiangang, LIU Lintao. Calibration of Scale Value for CHZ-Ⅱ Air-Sea Gravimeter [J]. jgg, 2020, 40(3): 323-326.